GMT00 @Track Air Interface Protocol
TRACGMT100AN001 67
Reserved
Backup Battery
Percentage
<=3
0 100
Reserved
Reserved
Reserved
Reserved
Send Time
14
YYYYMMDDHHMMSS
Count Number
4
0000 FFFF
Tail Character
1
$
$
<External Power Supply>: The voltage of the external power supply. If using command
AT+GTEPS to set the device report the external power supply voltage periodically with
fixed report, the device will send the current voltage along with +RESP:GTFRI message to
the backend server. If not set, this field will be empty.
<Report ID/Report Type>: Indicate the working mode of the fixed report and the type of the
message.
Report ID has four meanings as below.
1: fixed timing report.
2: fixed distance report.
3: fixed mileage report.
4: fixed timing and mileage report.
Report type has two meanings as below.
0: the normal fixed report.
1: corner report which indicates that the device just turns around a corner.
<Number>: The number of the GPS position included in the report message. In the message
+RESP:GTFRI, it probably includes one or several GPS position according to the setting of
<Send Interval> and <Check Interval>. If multi-position in one +RESP:GTFRI message, the
green part repeats.
<Ignition Time Count>: If ignition time counter function is enabled by the command
AT+GTHMC, total ignition time counted when engine is on will be reported in this field. It
is formatted with 5 hour digits and 2 minute digits and 2 second digits and ranges from
00000:00:00 99999:00:00. If the function is disabled, this field will be reserved.
<Analog1 Input 1>: The voltage of the analog input 1. If using command AT+GTAIS to set
the device report the analog input 1 periodically with fixed report, the device will send the
current voltage of the analog input 1 along with +RESP:GTFRI message to the backend
server. If not set, this field will be empty.
<Backup Battery Percentage>: The current volume of the backup battery in percentage.
+RESP:GTEPS,
If the external power supply monitoring is enabled by the command AT+GTEPS, the device will