3.2.8. External Power Supply Monitoring
The command AT+GTEPS is used to configure the parameters of external power supply
monitoring. The device will measure and monitor the voltage of the external power supply. If the
voltage of the external power supply matches the predefined alarm condition, the device will
report an alarm message +RESP:GTEPS to the backend server to notify the status of the external
power supply.
AT+GTEPS=
Example:
AT+GTEPS=gmt100,2,250,12000,3,2,1,1,0,0,1,,,,0007$
'0' – '9' 'a' – 'z' 'A' – 'Z'
<Mode>: Working mode of the external power supply monitoring.
0: Disable the external power supply monitoring.
1: Enable the external power supply monitoring. If the current voltage is within the
range of (<Min Threshold>, <Max Threshold>), the +RESP:GTEPS alarm will be
triggered.
2: Enable the external power supply monitoring. If the current voltage is outside the