Queclink GMT100 Spezifikationen Seite 24

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 111
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 23
GMT00 @Track Air Interface Protocol
TRACGMT100AN001 23
3.2.6. Digital Input Port Setting
The command AT+GTDIS is used to configure the parameters of 2 digital input ports. Input
<Ignition Detection> is dedicated for ignition detection. The digital input port 1 is customizable. If
the logical status is changed on the digital input port 1, the device will report message
+RESP:GTDIS to the backend server.
AT+GTDIS=
Example:
AT+GTDIS=gmt100,0,2,,,1,1,4,,,,,,,0005$
Parameter
Length(byte)
Range/Format
Default
Password
4 6
'0' '9' 'a' 'z' 'A' 'Z'
gmt100
Ignition Detection
1
0
0
Sample Period
<=2
0|1 12(×2s)
1
Reserved
0
Reserved
0
Input ID 1
1
1
1
Enable
1
0|1
0
Debounce Time
<=2
0 20(×10ms)
0
Reserved
0
Reserved
0
Reserved
0
Reserved
0
Reserved
0
Reserved
0
Serial Number
4
0000 FFFF
Tail Character
1
$
$
<Ignition Detection>: ID of the ignition detection port.
<Input ID 1>: the digital input port ID.
<Sample Period>: the sampling period of the non-interruptible input port.
<Enable>: Enable or disable the interrupt input.
0: Disable
1: Enable
<Debounce Time>: The time for debouncing.